Description
The LC-5060 high performance liquid chromatograph is a multi-functional laboratory analytical instrument that integrates high performance, high reliability and high sensitivity developed by our company. It can be equipped with a variety of detectors such as ultraviolet, evaporative light, differential indication, and diode array. The processing and customization of its core components are completed in the United States. Stable liquid flow, high-quality imported optical components, ultra-low noise, and excellent quality can provide you with trustworthy analysis results; powerful anti-control software enables data processing and reporting functions to flexibly cope with any requirements of analysis work; simple and user-friendly appearance design makes your use and maintenance more handy; super high cost performance is your best choice for chromatographic analysis, and the company's strong after-sales service team will relieve your worries.
Main Performance Features
●High-precision pulses: Compared with ordinary pumps, both time period and flow fluctuations are greatly reduced, which is achieved by using small volume and high frequency pistons to push. The reduction in fluctuations enable detectors such as ultraviolet detectors, electrochemical detectors, and fluorescence detectors to be detected within a high sensitivity range. At the same time, it can still ensure high flow accuracy at extremely low flow rates.
● Conveyor capacity: This pump can be used under high pressure or low pressure conditions, which can ensure high accuracy and low delay time under high pressure conditions.
● Precisely positioned optical path structure design, the use of high-precision and high-resolution imported stepper motors ensures the wavelength accuracy and stability of the instrument; the exclusive heat dissipation air path reduces the stability time of the instrument and reduces the impact of light source heating on the optical path system.
●The newly designed digital signal direct output mode does not require multiple conversions of internal analog signals and digital signals, and does not require the use of additional chromatographic data processing devices, which avoids signal distortion and interference caused by multiple conversions of the chromatographic signals, and reduces the baseline noise and drift of the instrument. The instrument adopts full-process digital filtering, which greatly improves the signal-to-noise ratio and anti-interference ability, and has excellent detection sensitivity and stability.
●Static wavelength scanning function can scan the spectral information of the sample within the wavelength range, provide scanning speed and scanning step parameter settings, which facilitates and quickly helps users determine the maximum absorption wavelength of the sample.
●Automatically record instrument accessories and their replacement information, instrument self-test error information, deuterium lamp usage time, number of lights, etc., more user-friendly settings, comply with the requirements of GLP specifications.
The chromatographic data processing system has the data tracking capabilities required by GLP, and can generate and input CDF files of AIA standard, and can be added and subtracted or displayed in multiple spectra. Instead of copying the set of methods commonly used in chromatographic data processing machines to the computer, it focuses on the intelligent processing of spectrogram data, striving to minimize the spectrum data processing knowledge that users need, and converting the only knowledge into something that is easy to understand. Its "professional" functions are still complete. The close combination with Microsoft Office, such as the ability to generate analysis reports, quantitative results (or a summary of multiple quantitative results) can be directly generated in Word, and the analysis records can be directly stored in the Access database, etc., so that in addition to obtaining component concentrations using the chromatography workstation, you can also complete the subsequent processing of chromatography analysis results, which will undoubtedly make your daily analysis work more handy.
Main technical parameters
Infusion pump specifications:
Components |
Specifications |
Pump Type |
Series Reciprocating Piston Pump |
Driving Mode |
Constant Flow Driving |
Flow Rate Range |
(0.001 - 9.999) mL/min |
Flow Rate Setting Step |
0.001 mL/min |
Flow Rate Accuracy |
±0.3% (1mL/min, 0.0 - 42.0MPa, Room Temperature) |
Flow Rate Precision |
≤0.05% (1mL/min, 0.0 - 42.0MPa, Room Temperature) |
Pressure Range |
(0.0 - 42.0) MPa |
Pressure Accuracy |
0.1MPa |
Pressure Limitation |
Maximum Pressure Limitation and Minimum Pressure Limitation |
Volume |
470×350×156 (mm) |
Weight |
16kg |
Operating Ambient Temperature Range |
(10 - 30) °C |
Operating Ambient Humidity Range |
(15 - 85) % RH |
Components |
Specifications |
Detector Type |
UV/Visible Light Detector |
Light Source |
Deuterium Lamp |
Wavelength Range |
190 - 700nm |
Wavelength Indication Error |
±2nm |
Spectral Bandwidth |
8nm |
Detection Cell Volume |
8 μL |
Baseline Noise |
≤ 1.0×10⁻⁵ AU (1mL/min, 100% Methanol, C18 Chromatographic Column) |
Baseline Drift |
≤ 2.5×10⁻⁴ AU/h (1mL/min, 100% Methanol, C18 Chromatographic Column) |
Minimum Detection Concentration |
≤ 3.0×10⁻⁹ g/mL (1mL/min, 100% Methanol, C18 Chromatographic Column) |
Volume |
470×350×156 (mm) |
Weight |
15kg |
Operating Ambient Temperature Range |
*10 - 30°C |
Operating Ambient Humidity Range |
*15 - 85% RH |